CADD-Solis Pump Manual: A Comprehensive Guide

This manual details the CADD-Solis pump‚ a vital medical device for controlled fluid delivery. Recent FDA clearances and launches‚ including the VIP system‚
highlight Smiths Medical’s advancements.

Understanding recalls and updated instructions is crucial for safe operation. This guide provides comprehensive information for healthcare professionals.

The CADD-Solis pump represents a significant advancement in ambulatory infusion technology‚ manufactured by Smiths Medical‚ a global leader in medical devices. This pump is designed for precise and reliable delivery of fluids‚ including medications and nutrients‚ directly to patients.

Recent developments‚ as of December 6‚ 2025‚ include FDA 510(k) clearances for both the standard CADD-Solis system and the specialized CADD-Solis VIP ambulatory infusion system. These clearances demonstrate the pump’s adherence to stringent safety and performance standards.

Furthermore‚ Smiths Medical has proactively addressed potential issues through recalls‚ focusing on updated use instructions to mitigate risks associated with false alarms and other operational concerns. This commitment to patient safety underscores the importance of understanding this manual thoroughly.

What is the CADD-Solis Pump Used For?

The CADD-Solis pump is a versatile medical device primarily utilized for the controlled delivery of fluids into a patient’s body. This encompasses a wide range of applications‚ including continuous infusions of pain management medications‚ antibiotics‚ chemotherapy‚ and nutritional support.

Specifically‚ the CADD-Solis VIP system expands functionality to include advanced pain management protocols‚ offering tailored treatment options for patients requiring specialized care. The pump’s precision ensures accurate dosing‚ minimizing the risk of under or over-infusion.

Its ambulatory nature allows patients greater freedom and mobility‚ facilitating treatment outside of traditional hospital settings. Understanding its diverse applications is key to maximizing its therapeutic benefits and ensuring optimal patient outcomes.

Key Features of the CADD-Solis System

The CADD-Solis system boasts several key features designed for enhanced safety and efficacy. Recent FDA 510(k) clearances demonstrate advancements in its technology and reliability. A core feature is its precision infusion capabilities‚ ensuring accurate medication delivery.

The VIP ambulatory system adds extended functionality‚ supporting diverse pain management strategies. Robust occlusion detection is paramount‚ preventing interruptions and ensuring continuous therapy. Connectivity and data logging capabilities facilitate comprehensive patient monitoring and treatment adjustments.

Smiths Medical’s commitment to updates and recalls underscores a dedication to patient safety. These features collectively position the CADD-Solis system as a leading solution for controlled fluid administration.

Understanding the Pump Components

The CADD-Solis system comprises a pump body with a display‚ compatible syringes‚ and a sophisticated occlusion detection system. Familiarity with these elements is essential.

Pump Body and Display

The CADD-Solis pump body is designed for durability and portability‚ facilitating various infusion settings. Its robust construction ensures reliable performance during ambulatory and hospital use. The integrated display serves as the primary interface for healthcare professionals‚ providing critical information regarding infusion parameters‚ pump status‚ and alarm conditions.

The display clearly presents infusion rates‚ total volume infused‚ battery life‚ and occlusion alerts. Intuitive navigation allows for easy programming and adjustment of settings. Users can readily monitor the pump’s operation and respond to any system messages. The display’s brightness is adjustable to optimize visibility in different lighting environments. Smiths Medical prioritizes a user-friendly interface to minimize errors and enhance patient safety.

Regularly inspect the pump body for any physical damage‚ and ensure the display is functioning correctly.

Syringe Options and Compatibility

The CADD-Solis system supports a range of syringe sizes to accommodate diverse infusion needs. Compatibility extends to various syringe materials and brands‚ offering flexibility for healthcare providers. Proper syringe selection is crucial for accurate and safe medication delivery‚ ensuring the pump functions optimally with the chosen configuration.

Always verify syringe compatibility with the CADD-Solis pump before initiating infusion. Refer to the pump’s documentation for a comprehensive list of approved syringes. Using non-compatible syringes may lead to inaccurate flow rates or pump malfunctions. The system is designed to recognize different syringe sizes automatically‚ simplifying the programming process.

Ensure syringes are securely loaded into the pump‚ following the manufacturer’s instructions.

Occlusion Detection System

The CADD-Solis pump incorporates a sophisticated occlusion detection system to ensure patient safety and accurate infusion. This system continuously monitors the pressure within the infusion line‚ identifying potential blockages that could compromise delivery. Upon detecting an occlusion‚ the pump will automatically pause infusion and trigger an alarm‚ alerting healthcare personnel.

The system differentiates between true occlusions and minor pressure fluctuations‚ minimizing false alarms. However‚ it’s crucial to investigate all alarms promptly. Troubleshooting steps may include checking the infusion site‚ tubing for kinks‚ or the syringe plunger for obstruction.

Recent recalls have addressed issues related to false alarms‚ highlighting the importance of updated software and adherence to manufacturer guidelines.

Setting Up the CADD-Solis Pump

Proper setup is essential for accurate infusions. This involves powering on‚ carefully loading the correct syringe‚ and precisely programming the desired infusion parameters.

Powering On and Initial Setup

Initiating the CADD-Solis pump requires a straightforward process. First‚ ensure the battery is adequately charged or connect the pump to a power source. Press and hold the power button until the display illuminates‚ indicating the pump is activating.

Upon startup‚ the pump will perform a self-test. Observe the display for any error messages during this phase; if errors appear‚ consult the troubleshooting section of this manual. The initial setup may prompt you to confirm the date and time‚ ensuring accurate infusion logging.

Familiarize yourself with the display interface‚ noting the various icons and their corresponding functions. Proper initial setup is paramount for reliable and safe operation of the CADD-Solis system‚ guaranteeing precise medication delivery.

Loading the Syringe

Correct syringe loading is critical for accurate infusion; Ensure the syringe is compatible with the CADD-Solis pump‚ referencing the syringe options section for approved models. Gently open the syringe holder and carefully insert the pre-filled syringe‚ aligning it securely within the designated slot.

Verify the syringe is firmly seated and that the plunger is fully depressed before closing the syringe holder. The pump will then recognize the syringe type and volume. Incorrect loading can lead to inaccurate delivery or pump malfunction.

Always inspect the syringe for any damage or leaks prior to loading. Proper syringe loading ensures consistent and reliable performance of the CADD-Solis infusion system.

Programming Infusion Parameters

Accurate programming is essential for patient safety. After loading the syringe‚ navigate the CADD-Solis pump’s interface to set the desired infusion rate‚ typically in milliliters per hour (mL/hr). Input the total volume to be infused‚ and the pump will calculate the infusion duration.

Carefully confirm all entered parameters before initiating therapy. The system allows for programming of bolus doses‚ which should be administered with caution and according to physician orders.

Review the programmed settings one final time to prevent medication errors. The CADD-Solis pump offers customizable profiles for various infusion protocols‚ streamlining the programming process.

Operating the CADD-Solis Pump

Initiate infusions with a simple start command‚ and adjust rates as needed. Utilize the bolus function cautiously‚ following medical directives. Monitor alarms diligently.

Starting and Stopping Infusion

To begin an infusion‚ ensure the syringe is securely loaded and the programmed parameters are verified. Press the ‘Start’ button; the pump will initiate delivery according to the set infusion rate. The display will show active infusion status‚ including remaining volume and time.

Stopping the infusion is equally straightforward. Press the ‘Stop’ button to immediately halt delivery. The pump will cease operation‚ and the display will reflect the stopped status.

For temporary pauses‚ some models may offer a ‘Pause’ function‚ allowing for brief interruptions without losing programmed settings. Always confirm complete cessation of flow visually after stopping‚ especially for critical medications. Proper operation ensures patient safety and accurate drug delivery.

Adjusting Infusion Rates

Modifying the infusion rate during therapy is possible with the CADD-Solis pump‚ but requires careful attention. Access the programming menu using the designated buttons on the pump’s interface. Navigate to the rate setting and utilize the up/down arrows or numerical keypad to input the desired flow rate.

Confirm the new rate before saving‚ as incorrect adjustments can significantly impact drug delivery. The pump will typically display a confirmation prompt. Once saved‚ the pump will gradually adjust to the new rate.

Always document any rate changes in the patient’s record‚ including the time‚ old rate‚ and new rate. This ensures a clear audit trail and supports safe medication administration.

Bolus Delivery Function

The CADD-Solis pump offers a bolus delivery function‚ allowing for a supplemental‚ rapid infusion of medication. Access this feature through the pump’s programming menu; it’s typically a separate option from continuous infusion settings. Input the desired bolus volume carefully‚ verifying the dosage with the prescribed order.

Initiate the bolus with a dedicated button press‚ and observe the pump to ensure proper delivery. The pump will administer the bolus volume in addition to the continuous infusion rate.

Document the bolus administration‚ including the time‚ volume‚ and reason for delivery‚ in the patient’s medical record. Always adhere to institutional policies regarding bolus administration.

Safety Features and Alarms

The CADD-Solis pump incorporates crucial safety features‚ including occlusion detection and alarms for low battery or system malfunctions.
Promptly address any alerts to ensure patient safety.

Occlusion Alarms and Troubleshooting

Occlusion alarms on the CADD-Solis pump indicate a blockage in the infusion set‚ preventing fluid delivery. These alarms are critical safety features‚ designed to protect the patient. Upon activation‚ immediately verify the infusion site for swelling or signs of infiltration.

Troubleshooting steps include gently flushing the line (if protocol allows) and checking for kinks in the tubing. Ensure the syringe is properly seated and not compressed. If the occlusion persists after these checks‚ replace the infusion set and syringe.

Recent recalls have addressed potential false alarms‚ emphasizing the importance of following updated use instructions provided by Smiths Medical. Always document alarm events and troubleshooting steps taken in the patient’s record.

Low Battery Alarm

The CADD-Solis pump features a low battery alarm to alert users of insufficient power. This alarm indicates the battery charge is nearing depletion‚ potentially interrupting infusion. Upon activation‚ immediately connect the pump to a power source using the provided AC adapter.

If AC power isn’t available‚ replace the battery with a fully charged‚ compatible unit. Ensure the pump remains connected to power or utilizes a fresh battery throughout the infusion duration; Ignoring the low battery alarm could lead to therapy interruption and compromise patient safety.

Regular battery checks and proactive replacement are crucial for uninterrupted operation. Refer to the ‘Battery Management and Replacement’ section for detailed guidance on proper battery handling and disposal.

System Malfunction Alarms

The CADD-Solis pump is equipped with alarms to detect internal system malfunctions; These alarms signal potential issues affecting pump functionality and infusion accuracy. Upon encountering a system malfunction alarm‚ immediately halt the infusion and assess the situation.

Do not attempt to troubleshoot or repair the pump independently. Contact qualified biomedical personnel or Smiths Medical support for assistance. Recent recalls highlight the importance of adhering to updated use instructions to mitigate potential risks associated with false alarms or operational errors.

Document the alarm details and any observed symptoms. Proper reporting aids in identifying and resolving underlying issues‚ ensuring continued safe and effective pump operation.

Maintenance and Care

Regular cleaning‚ proper battery management‚ and timely software updates are essential. These practices ensure optimal CADD-Solis pump performance and longevity‚ maintaining patient safety.

Cleaning the Pump

Maintaining a clean CADD-Solis pump is paramount for preventing healthcare-associated infections and ensuring accurate medication delivery. Always disconnect the pump from the power source before initiating any cleaning procedure. Utilize a soft‚ slightly dampened cloth with a mild detergent solution to gently wipe down the pump’s exterior surfaces.

Avoid abrasive cleaners or excessive moisture‚ as these can damage the pump’s components. Pay particular attention to the display screen and keypads‚ ensuring they are free from debris. The pump’s casing should be regularly inspected for cracks or damage that could harbor contaminants.

Do not immerse the pump in any liquid. Following cleaning‚ ensure the pump is thoroughly dried before reconnecting it to a power source or loading a syringe; Refer to the full CADD-Solis manual for detailed cleaning instructions and approved disinfectant solutions.

Battery Management and Replacement

Proper battery management is crucial for uninterrupted CADD-Solis pump operation. The pump utilizes rechargeable batteries‚ and their lifespan depends on usage patterns and charging frequency. Regularly monitor the battery level displayed on the pump’s screen and initiate charging when indicated.

Only use approved Smiths Medical chargers to avoid damaging the battery. Avoid completely discharging the battery‚ as this can reduce its overall lifespan. When replacing the battery‚ always use a genuine Smiths Medical replacement battery to ensure compatibility and performance.

Dispose of used batteries responsibly‚ following local regulations. Refer to the CADD-Solis pump manual for specific battery specifications and replacement procedures. A low battery alarm will alert users to the need for charging or replacement‚ preventing unexpected pump shutdowns during infusion.

Software Updates and Firmware

Maintaining up-to-date software and firmware is essential for optimal CADD-Solis pump performance and security. Smiths Medical periodically releases updates to address potential issues‚ enhance functionality‚ and improve safety features. These updates often follow FDA clearances and recall resolutions.

Check the Smiths Medical website regularly for available updates. The pump may prompt you to install updates automatically‚ or you may need to download them manually and transfer them to the pump via a compatible interface.

Always follow the provided instructions carefully during the update process. Interrupting the update can potentially damage the pump’s software. Updated firmware ensures compatibility with the latest features and addresses identified vulnerabilities‚ contributing to patient safety and reliable operation.

Troubleshooting Common Issues

Addressing pump malfunctions quickly is vital. Common problems include power failures‚ infusion start failures‚ and unexpected alarms‚ often linked to recalls or updates.

Refer to this section for solutions and ensure patient safety.

Pump Not Powering On

If the CADD-Solis pump fails to power on‚ several checks are necessary. First‚ verify the battery is correctly installed and adequately charged. A low battery alarm may precede complete power loss‚ but ensure a fully charged battery is used for testing.

Next‚ inspect the power adapter and connection if using AC power. Confirm the outlet is functioning correctly. If using a new battery or a confirmed working power adapter still results in no power‚ a potential system malfunction may exist.

Do not attempt to disassemble the pump. Contact Smiths Medical technical support for assistance‚ referencing any recent FDA clearances or recalls related to power issues. Document the troubleshooting steps taken before contacting support for efficient resolution.

Infusion Not Starting

If the CADD-Solis pump displays no infusion despite powering on‚ systematically check several components. First‚ confirm the syringe is correctly loaded and compatible with the pump‚ referencing syringe options and compatibility guidelines. Ensure proper seating and no obstructions are present.

Next‚ verify the programmed infusion parameters are accurate and not set to zero. An active occlusion alarm could also prevent infusion; address any occlusion issues first. Review recent recalls related to alarm functionality.

If no alarms are present and the syringe is correctly loaded‚ a potential system malfunction may be occurring. Contact Smiths Medical support‚ detailing the steps taken and referencing any relevant FDA 510(k) clearances.

Unexpected Alarms

Unexpected alarms on the CADD-Solis pump require immediate attention and systematic troubleshooting. First‚ carefully note the alarm type displayed‚ as this dictates the appropriate response. Frequent occlusion alarms‚ even without visible blockage‚ may indicate a pump issue – consult the occlusion detection system section.

Recent Smiths Medical pump recalls have addressed false alarm issues; verify if your pump is affected by any updates or revised instructions. A low battery alarm‚ even with a seemingly charged battery‚ could signal a failing power source.

If the alarm persists after addressing common causes‚ a system malfunction is possible. Document all steps and contact Smiths Medical support‚ referencing any relevant FDA clearances for assistance.

Recalls and FDA Clearances

Recent Smiths Medical recalls address potential false alarms and usage instructions. The CADD-Solis system received FDA 510(k) clearance‚ ensuring safety and efficacy standards are met.

Recent FDA 510(k) Clearances

Smiths Medical has consistently pursued and obtained 510(k) clearances from the U.S. Food and Drug Administration (FDA) for the CADD-Solis platform and its expanding capabilities. These clearances are pivotal‚ demonstrating substantial equivalence to legally marketed predicate devices and validating the safety and effectiveness of the system.

Notably‚ the CADD-Solis VIP ambulatory infusion system received 510(k) clearance‚ enabling its launch and wider availability to patients requiring portable infusion therapy. Furthermore‚ clearance was granted for the CADD-Solis pain management system‚ broadening the pump’s application beyond general infusion to specialized pain control protocols.

These FDA approvals signify rigorous evaluation and adherence to quality standards‚ assuring healthcare providers and patients of the CADD-Solis pump’s reliability and performance. Continuous pursuit of these clearances underscores Smiths Medical’s commitment to innovation and patient safety.

Smiths Medical Pump Recalls ౼ Details

Smiths Medical has initiated recalls of certain CADD-Solis ambulatory infusion pumps to address identified issues impacting patient safety and device functionality. These recalls primarily focus on updating use instructions to mitigate the risk of false alarms‚ which could delay necessary therapy or cause undue alarm to patients and clinicians.

Specifically‚ the recalls address three key problems: potential false alarms‚ issues that could lead to under-infusion‚ and concerns regarding device operation. Updated instructions are being distributed to healthcare providers to ensure proper pump usage and minimize these risks.

The company emphasizes the importance of reviewing and implementing the updated guidance to maintain patient safety. Details regarding affected lot numbers and specific corrective actions are available through Smiths Medical’s official recall notifications and the FDA’s website.

Impact of Recalls on Pump Usage

The recent Smiths Medical CADD-Solis pump recalls necessitate careful consideration for continued pump utilization. Healthcare facilities must immediately review the recall notifications to determine if their devices are affected and implement the provided corrective actions‚ primarily focusing on updated use instructions.

Clinicians should prioritize thorough training on the revised procedures to prevent potential issues like false alarms or under-infusion. Patient monitoring remains crucial‚ even with updated protocols‚ to ensure accurate and safe medication delivery.

While the recalls don’t mandate immediate cessation of pump use‚ adherence to the updated guidance is paramount. Facilities should document all training and implementation efforts to demonstrate compliance and prioritize patient well-being during and after the recall period.

Advanced Features

The CADD-Solis system offers VIP ambulatory infusion‚ pain management capabilities‚ and connectivity for data logging. These features enhance clinical workflows and patient care.

CADD-Solis VIP Ambulatory Infusion System

The CADD-Solis VIP system represents a significant advancement in ambulatory infusion technology. Launched by Smiths Medical‚ this system is designed to provide patients with greater freedom and flexibility while receiving continuous intravenous therapy. It’s particularly suited for long-term infusions‚ allowing individuals to maintain a more active lifestyle.

Key benefits include a compact and lightweight design‚ enhancing patient comfort and mobility. The VIP system supports various infusion needs‚ offering precise and reliable fluid delivery. Smiths Medical emphasizes the system’s ease of use for both patients and healthcare providers. Recent FDA clearance underscores the system’s safety and efficacy‚ solidifying its position as a leading solution in ambulatory care.

This system expands the capabilities of the CADD-Solis platform‚ catering to a broader range of patient requirements and treatment protocols.

Pain Management System Applications

The CADD-Solis pump demonstrates significant utility within pain management protocols‚ offering precise and customizable medication delivery. Smiths Medical received FDA 510(k) clearance for its CADD-Solis pain management system‚ expanding its application beyond general infusion therapy. This clearance highlights the pump’s suitability for delivering analgesics‚ including opioids and local anesthetics‚ for both acute and chronic pain conditions.

The system allows clinicians to tailor infusion parameters to individual patient needs‚ optimizing pain relief while minimizing potential side effects. Programmable bolus options and adjustable infusion rates contribute to personalized pain management strategies.

Effective pain control is crucial for patient recovery and quality of life‚ and the CADD-Solis system provides a reliable tool for achieving these goals.

Connectivity and Data Logging

The CADD-Solis system is evolving with enhanced connectivity features‚ though specific details regarding data logging capabilities require further clarification from Smiths Medical’s official documentation. Modern infusion pumps increasingly integrate with hospital information systems (HIS) and electronic medical records (EMR) to streamline workflow and improve patient safety.

Potential connectivity features could include wireless data transfer‚ allowing for remote monitoring of infusion parameters and automated documentation of therapy delivery. This capability supports proactive intervention and reduces the risk of errors.

Robust data logging is essential for quality assurance and regulatory compliance‚ providing a comprehensive audit trail of infusion events.